VS-P03 RETROFIT PORTO, PT SAMPLE ENTRY

Rail Concourse

A stone-clad station hall where every announcement arrived three times. We tuned the room and the loudspeakers together until it arrived once.

CLIENT
Rail operator
TYPE
Retrofit
FOCUS
Speech intelligibility, PA
SIZE
2,400 m²
STATUS
Complete, 2025
LOCATION
41.15°N 8.61°W
FIG.MEASUREDSTI 0.41 → 0.57 (CONCOURSE AVG)
STI ALONG THE CONCOURSE (DISTANCE IN M) BEFOREAFTER
0.30 0.40 0.50 0.60 0.70 10 20 30 40 50 60 70 80 90 100 VOICE ALARM MIN. 0.50
P03NOTES
01

Brief

Passengers couldn’t make out platform changes, and the voice alarm system had failed its intelligibility test. New loudspeakers on their own had already been tried.

02

Approach

We modelled the hall and the sound system together and tried different loudspeaker positions and angles in the model. Absorption went into the roof coffers, out of sight from the floor. The existing line arrays were rehung lower and aimed away from the stone.

03

Outcome

Announcements are now clear along the full length of the concourse, and the voice alarm system passes comfortably above the 0.50 STI it needs.