Aula Lecture Theatre

A 1960s concrete lecture theatre where anyone past the tenth row was mostly guessing. We gave the back of the room its voice back.

CLIENT
University
TYPE
Retrofit
FOCUS
Speech intelligibility
SIZE
420 seats
STATUS
Complete, 2025
LOCATION
52.00°N 4.37°E
FIG.MEASUREDSTI 0.48 → 0.67 (REAR ROWS)
STI BY SEATING ROW BEFOREAFTER
0.30 0.40 0.50 0.60 0.70 0.80 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GOOD 0.60
P01NOTES
01

Brief

Lecturers were hoarse by the end of the day and students in the rear half relied on the slides. The university wanted it fixed without closing the hall for a term or covering the board-marked concrete the building is known for.

02

Approach

We measured speech transmission at forty seats, then built a model that matched those measurements. Listening sessions let the facilities team hear a lecture from row fourteen, before and after. The final scheme adds absorption to the rear wall and ceiling soffits, and splits the loudspeakers into three delayed zones.

03

Outcome

The work was done over two summer months. The back row now hears about as well as the front row used to, and nobody needs the microphone turned up to be heard.